Japan Datacenter
DC Address- 2-1-7, Higashi-shinagawa Shinagawa-ku, Tokyo, Japan 140-0002
- Break Room
- Crash Carts
- Loaner Tools
- Open since 2002
- 99.99% uptime
- low latency interconnections
- ISO/IEC 27001 certified
- Only brand networking hardware
- 117,000 square meters server area
Air conditioning
- Redundant climate control system with a mixture of direct and indirect cooling
- Air exchangeby enormously efficient equipment generation of Weiss Air Conditioning
- Primary cooling by suction and filtration of outside air
- Mixing of fresh air with indoor air for a constant temperature level
- 90% of the hours in a year will not require any mechanical refrigeration, since only external air is filtered and mixed.
- 9% of the annual hours will only require a small amount of mechanical refrigeration.
- 1% of the annual hours require mechanical cooling, because the outside air is warmer than the air inside.
- Containment of the cold aisles with sliding doors and roofs to avoid mixing effects: The cold air is targeted and used in the exact amount needed. There is no loss, as only the servers are air-conditioned.
Energy
- Redundant uninterruptible power supply concept with up to 2x1000kVA performance
- Green Power UPS systems manufacturer Socomec with an efficiency of 96%
- Transport of energy through low loss power rails with 40% higher efficiency
- Dimensioning of all components for significantly higher payload to avoid energetically inefficient heat
- Two separate power feeds through two sub-distributions for each rack
- 10kW+ power consumption per rack possible
- Direct neighboring substation
- 3-stage surge protection: primary protection in the main distribution, medium / fine protection
IP connectivity
- Two separate fiber pairs
- Useage of the CWDM technology for high scalability of bandwidth
- Routing through modern Juniper routers
- Core Switching by modern Cisco switches
- Uplinks in either 100Mbit, 1Gbit or 10Gbit
- Redundant network supply through numerous carriers such as Tiscali International and the German Telekom
- Peering connections trough various exchangepoints such as DECiX, AMSiX, KleyReX, ViX und NIX.
Access, Security and Logging
- Biometric access control system with fingerprint reader
- Logging of all entrances and exits
- Division in 3 access-restricted areas
- Separated and secure rooms for batteries, UPS and Power Supply
- Access only trough 2 channels with security terminals
- Camera surveillance and recording systems with infrared
- 24×7 on-site personnel
Server parking areas
- Optically uniform overall picture by using identical racks
- 47 U at 1000 mm depth per rack
- CAT7 cabling
- Separate power and data lines
- High Perforation for optimal airflow
- Closure of open rack units with empty plates to prevent air mixing effects
Energy
- Control of all light and secondary consumers through a central bus system
- High number of areas of light to reduce energy consumption
- CO2 fire extinguishers in all areas immediately accessible
- System to directly alert the technical staff on site and external staff